ventilation-systems

HRV 2 Q Plus

Highly energy efficient heat recovery ventilation unit

For use in medium to large sized dwellings

HRV2 Q PlusThe revolutionary compact HRV2 Q Plus continuously running whole
house ventilation unit with heat recovery is independently tested by
the BRE and is EST Best Practice compliant. The HRV2 Q Plus gives
cutting edge performance usually only associated with much larger
and more costly products.

The combination of very low power consumption and a highly efficient
heat exchanger is specifically designed to enhance SAP performance via Appendix Q, yet small enough to be easily incorporated into medium sized dwellings. The HRV2 Q Plus is now available with improved features and in three model options, two of which include Summer Bypass.

Features & Benefits

  • Compact unit can be fitted in cupboards or loft spaces
  • Very low power consumption / specific fan power
  • Constant volume fans
  • Highly efficient heat exchanger; up to 90%
  • Three versions available (all the same dimensions): ‘Standard’, ‘Summer Bypass and Duct Heater Connection’, or ‘Summer Bypass c/w SUMMERboost and Duct Heater Connection’
  • Standard version has a Summer Mode feature to help reduce dwelling overheating
  • Intelligent controller, quick and easy to commission
  • Fully adjustable boost overrun timer 0-60 minutes; can be used with non-latching (momentary) switches to prevent from being accidently left in boost mode
  • Accepts 125mm or 150mm diameter ducting, no adaptors required
  • Intelligent frost protection, stepped reduction of supply air rates prevents freezing
  • Setback option for unoccupied periods
  • Demand Control Ventilation ready
  • Volt free switching control
  • G3 filters as standard, G4 & F7 options
  • Lightweight for easy handling
  • Quick fix via mounting bracket
  • Patented

 

HRV2 Q Plus
Exhaust Terminal
Configuration*
Fan Speed
Setting
Specific Fan
Power
(W/l/s)
Heat
Exchange
Efficiency (%)
Energy Saving Trust Best
Practice Performance
Compliant
Kitchen + 1 additional wet room   -   -   -   -
Kitchen + 2 additional wet rooms 100% variable 0.63 90 Yes
Kitchen + 3 additional wet rooms 100% variable 0.69 90 Yes
Kitchen + 4 additional wet rooms 100% variable 0.77 89 Yes
Kitchen + 5 additional wet rooms 100% variable 0.91 88 Yes
Kitchen + 6 additional wet rooms 100% variable 1.04 88 No
Kitchen + 7 additional wet rooms 100% variable 1.23 87 No

Figures taken from the BRE Test Results.

*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Noise Performance - details on request

HRV2 Q Plus dimensionsHRV2 Q Plus typical application

Description

Titon HRV2 Q Plus whole house central mechanical supply and extract unit with heat exchanger.

Product Code

TP401A
Filter: XP40132/099

TP401ABD (with Summer Bypass and Duct Heater Connection)

TP401ABS (with SUMMERboost, Summer Bypass and Duct Heater Connection)
G3 filter: XP40133/099
G4 filter: XP46133/099

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation. SAP Appendix Q tested (www.sap-appendixq.org.uk).

Exceeds requirements of Building Regulations Approved Document L (England & Wales)

EU RoHS Directive compliant.

Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC)
EN 60335-1:2002/A2:2006, EN 60335-
2-80:2003/A1:2004. CE Marked.

Other non-UK info available on request.

Specification

Dimensions: 715mm wide x 490mm high (excluding ports) x 415mm deep (426mm with mounting bracket)

Weight: 24kg.

Finish: White Paint.

Materials
Housing: Zintec sheet steel housing, powder coated white

Internals: Expanded polypropylene (EPP)

Heat exchanger: Polystyrene

Internal insulation: Closed cell foamed
Nitrile rubber, class ‘O’ fire rating

Standard filters: Grade G3 synthetic
filters, flame resistance to BS5588

Guarantee period: 3 years (UK only

Electrical: 230V 50Hz

Installation: Install in accordance with Good Practice, such as the Domestic Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association recommendations - details on request.

Maintenance: Annual Service and filter
change recommended. Uses long life
washable grade G3 filters.

More information

ventsales@titon.co.uk / 01206 713800

HRV2 Q Plus nominal fan performance graph