ventilation-systems

HRV 3 Q Plus

Highly energy efficient heat recovery ventilation unit

For use in large sized dwellings

HRV3 Q PlusThe revolutionary HRV3 Q Plus whole house ventilation unit, independently tested by the BRE and shown to be EST Best Practice compliant, is a unique heat recovery ventilation unit. The HRV3 Q Plus gives cutting edge performance usually only associated with much larger and more costly products.

The combination of very low power consumption and a highly efficient heat exchanger is specifically designed and manufactured to enhance SAP performance via Appendix Q of Part L.

Features & Benefits

  • Compact - unit is small and can be fitted in cupboards or loft spaces.
  • Very low power consumption / specific fan power.
  • Highly efficient heat exchanger - up to 90%, extremely efficient for its size.
  • Independently SAP Q tested by the BRE.
  • EST Best Practice compliant - assists in achieving high dwelling energy efficiency ratings.
  • Easy installation with quick fix mounting bracket.
  • Standard 15mm condensate drain connection.
  • Quick commissioning facility with 5 or 10 minute boost over-run.
  • Full commission facility for ultimate efficiency with 5, 10, 15 or 20 minute
  • boost over-run.
  • Ports accept 125mm or 150mm diameter ducting, no adaptors required.
  • Frost protection.
  • Versatile energy saving boost control with adjustable over-run timer, when used with non-latching (momentary) switch unit cannot be accidentally left in boost mode.
  • Demand Control Ventilation ready.
  • Lightweight, 24.5kg - saves transit / handling costs and installation time.
  • Full range of ducting and ancillaries available.
  • Patent Applied For.

 

HRV3 Q Plus
Exhaust Terminal
Configuration*
Fan Speed
Setting
Specific Fan
Power
(W/l/s)
Heat
Exchange
Efficiency (%)
Energy Saving Trust Best
Practice Performance
Compliant
Kitchen + 3 additional wet rooms 100% variable 0.66 90  Yes
Kitchen + 4 additional wet rooms 100% variable 0.78 89 Yes
Kitchen + 5 additional wet rooms 100% variable 0.91 88 Yes
Kitchen + 6 additional wet rooms 100% variable 1.05 88 No
Kitchen + 7 additional wet rooms 100% variable 1.22 87 No

Figures taken from the BRE Test Results.

*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Noise Performance - details on request

HRV3 Q Plus dimensions

Description

Titon HRV3 Q Plus whole house central mechanical supply and extract unit with heat exchanger.

Product Code

TP402

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation. SAP Appendix Q tested (www.sap-appendixq.org.uk).

Exceeds requirements of Building Regulations Approved Document L (England & Wales).

EU RoHS Directive compliant.

Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2-80:2003/A1:2004. CE Marked.

Specification

Dimensions: 715mm wide x 490mm high (excluding ports) x 415mm deep (426mm with mounting bracket).

Weight: 24.5kg.

Finish: White Paint.

Housing: Zintec sheet steel housing, powder coated white.

Internals: Expanded polypropylene (EPP).

Heat exchanger: Polystyrene.

Internal insulation: Closed cell foamed. Nitrile rubber, class ‘O’ fire rating.

Filters: Grade G3 synthetic filters, flame resistance to BS5588.

Guarantee period: 3 years.

Electrical: 230V 50Hz.

Installation: Install in accordance with Residential Ventilation Association Good Practice recommendations - details on request.

Maintenance: Annual Service and filter change recommended. Uses long life washable grade G3 filters.

More information

ventsales@titon.co.uk / 01206 713800