ventilation-systems

HRV 10M Q Plus

Mechanical Ventilation with Heat Recovery unit (MVHR) BUY NOW

For use in medium to large sized dwellings

HRV10M Q PlusThe HRV10M Q Plus continuously running whole house ventilation unit with heat recovery has been specifically designed to give improved performance over older models, in line with new build design requirements.

Combining of extremely low power consumption and a highly efficient heat exchanger specifically designed to enhance SAP performance via Appendix Q and can be incorporated into larger apartments or dwellings.

The Eco versions offer a 100% airflow diverting Summer Bypass, recognised and listed in the UK Product Characteristics Database. They also include intelligent humidity options and can be fitted with the auralite® status indicator or the auramode® and aurastat® controllers.

Features & Benefits

  • Extremely low Specific Fan Power of 0.48 W/l/s
  • Highly efficient heat exchanger; up to 92%
  • Lightweight EPP construction giving high levels of thermal insulation
  • Accepts 150mm or 125mm diameter ducting
  • Independent fan adjustment
  • Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing
  • Setback facility to reduce ventilation where local regulations allow
  • Fully adjustable boost overrun timer 0-60 minutes; can be used with non-latching (momentary) switches to prevent unit from being accidentally left in boost mode
  • Intelligent controller, quick and easy to commission
  • EPP moulded 150-125mm low resistance insulated port adaptors included as standard
  • Lightweight for easy handling
  • Volt free switching control
  • Pleated G4 filters as standard. F7 on request (standard unit only)
  • Quick fix mounting bracket
  • Patented features
  • Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Basic version;

  • Summer Mode

Eco versions;

  • Intelligent Summer Bypass & humidity controls
  • SUMMERboost® facility

Eco HMB Models;

Eco B Models;

  • Compatible with aura range; aurastat®auramode® and auralite® (TP519) controllers
  • Duct heater control (requires independent power supply)
  • BMS compatible via RS485

For explanations of HRV features, click here.

Click here to read case studies on the successful application of the HRV10 Q Plus.

 

System 4

 

Exhaust Terminal
Configuration*
Fan Speed
Setting
Specific Fan
Power
(W/l/s)
Heat
Exchange
Efficiency (%)
Kitchen + 1 additional wet room 100% variable 0.52 92
Kitchen + 2 additional wet rooms 100% variable 0.48 92
Kitchen + 3 additional wet rooms 100% variable 0.51 92
Kitchen + 4 additional wet rooms 100% variable 0.55 91
Kitchen + 5 additional wet rooms 100% variable 0.62 91
Kitchen + 6 additional wet rooms 100% variable 0.74 90
Kitchen + 7 additional wet rooms 100% variable 0.87 89

Figures taken from the BRE Test Results.

*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Noise Performance - see the Documentation tab on this page

Performance of the Eco versions may differ slightly and are available on request.

HRV10 Q Plus dimensions

 

Product Code

HRV10M Q Plus - TP441A - Energy Rating A
HRV10M Q Plus HMB Eco auralite® ready - TP441HMB - Energy Rating A
HRV10M Q Plus B Eco aurastat® ready  - TP481B - Energy Rating A+
Filters:
XP44022/099 - G4 Filter set fitted as standard
Eco versions:
XP44023/099 - G4 Bypass filter set fitted as standard

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398
SAP Appendix Q tested
(www.sap-appendixq.org.uk)
Exceeds requirements of Building
Regulations Approved Document L
(England & Wales)  
EU RoHS Directive compliant  
Conforms to requirements of EC council
directives relating to Electromagnetic
Compatibility and Electrical Safety: 2006/95/EC (LVD)
2004/108/EC (EMC)
EN 60335-1:2002/A2:2006
EN 60335-2-80:2003/A1:2004
CE Marked.
Other non-UK info available on request

Specification

Dimensions: HRV10M Q Plus 800mm wide x 675mm high (excluding ports) x 495mm deep (505mm with mounting bracket).
Weight: HRV10M Q Plus – 31kg
Finish: HRV10M Q Plus – White Paint
Materials: Expanded polypropylene
(EPP), Heat Exchanger – Polystyrene,
Internal Insulation – Closed cell foamed, Nitrile rubber, class ‘O’ fire rating,
Standard filters: Grade G4 pleated panel filters. NB: Except HRV10M Q Plus
Housing: Zintec sheet steel, powder
coated.
Guarantee period: 3 years (UK only)
Electrical: 230V ~ 50/60Hz, 3A fuse
Installation: Install in accordance with
Good Practice, such as the Domestic
Ventilation Compliance Guide (England &
Wales) and the Residential Ventilation
Association recommendations.
Maintenance: Service and filter
clean/replacement subject to local
environment - see Product Manual.

More information

ventsales@titon.co.uk / 01206 713800

 

 

Nominal fan performance - Eco Versions

HRV10 Q Plus Eco performance graph

All units offer 100% variable speed control.
*@FID (0 Pa)